If your gas furnace in Culver, IN is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Culver, IN. McGrath Refrigeration has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on McGrath Refrigeration to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Culver, IN

We provide gas furnace repair in Culver, IN

Get Your Quote Today

Replaced Pressure Switch On Furnace. Unit Worked As It Should.
Jim, H. Culver, IN
02-28-2024
Thermostat Was In Off Mode When I Got There. Turned Thermostat On By The Time I Got Downstairs The Furnace Had Lit And Was Running. Cleaned Flame Sensor, Drain Line And Pressure Switch Ports.
Jim, H. Culver, IN
01-10-2024
Checked Furnace, Found Drain Line Plugged. There Must Have Been Some More Debris In Flue Pip That I Couldn't Get To With Sweeper The First Time. Cleaned Tubing And Furnace Ran Ok.
Rich, F. Culver, IN
12-14-2023
Installed The Vessel Plate And Replaced The Burners. Lowered The Gas Pressure And Raised The Blower Speed.
joy, m. Culver, IN
12-14-2023
Luxaire TG9S060B12MP11
Checked Furnace, Found Draft Inducer Wheel Rubbing. Changed Draft Inducer And The Unit Would Not Pull In Pressure Switch. Cut Flue Pip Out And Found Bee Nest In Pipe. Removed Nest, Unit Ran Ok
Rich, F. Culver, IN
12-11-2023
The Furnace Was Igniting For About 30 Seconds. And Then The Flames Would Go Out. I Could Hear The Inducer Motor. Gargling Water. The Drain Lines Had PVC Shavings In Them. I Cleared The Drain Lines. I Ran The Machine For 10 Minutes And The Flames Went Out. I Noticed That The Drain Trap Was Missing On The Furnace
John, L. Culver, IN
11-30-2023
Cleaned The Burners On The Furnace. Raised The LP Gas Pressure On The Furnace.
Daniel, T. Culver, IN
11-13-2023
Checked Furnace Found Bad Rollout Switch
May, C. Culver, IN
10-03-2023
Luxaire TG9S060B12MP11
Replaced The Transformer On A Luxaire TG9S060B12MP11 Gas Furnace.
Rich, F. Culver, IN
01-31-2023
Amana AMH950703BXA
Client Had An Amana AMEC960803BNAC Gas Furnace That Had A Gas Valve And Flame Sensor. Technician Replaced Them Both And Unit Is Functioning Properly
Sheryl, V. Culver, IN