Furnace Service and Repair

If your gas furnace in North Judson, IN is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in North Judson, IN. McGrath Refrigeration has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on McGrath Refrigeration to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in North Judson, IN

We provide gas furnace repair in North Judson, IN

Get Your Quote Today

I Replaced The Inducer Motor And Air Filter. The Furnace Is Working Properly.
Jim, D. North Judson, IN
03-13-2024
I Braced The Return Ductwork With A Piece Of Metal. The Unit Is No Longer Flexing The Ductwork And Making A Noise
Bob, K. North Judson, IN
03-13-2024
Found Furnace Blower Seized Up Removed Old Blower And Replaced With New One Furnace Back To Normal Operation
Ron, R. North Judson, IN
03-05-2024
I Replaced The Indoor Blower Housing And Fan Blade And Motor With Capacitor. The Unit Is Working Properly.
Debbie, V. North Judson, IN
03-05-2024
Checked Furnace Found Drain Line Plugged Cleaned Drain Line And Checked Furnace. Furnace Ran As It Should. The Unit Was Flashing Ignition Failure And Not Pressure Switch. If It Happens Again May Need New Board.
Tim, K. North Judson, IN
03-05-2024
Checked Furnace Found It To Completely Shut Down Mid Cycle For No Reason Furnace Needs New Board. Changed Board And Furnace Ran As It Should
Lee, A. North Judson, IN
03-05-2024
Furnace Was Running When We Got Here. Cleaned Flame Sensor And Drains Furnace Ran As It Should.
Laura, B. North Judson, IN
02-28-2024
Installed New Thermostat And Unit Ran As It Should.
Julie, C. North Judson, IN
02-22-2024
Replaced Pressure Switch
Joe, J. North Judson, IN
01-31-2024
Checked Furnace The Control Board Was Flashing 1 Time Which Indicated A Lock Out Due To Flame Failure. The Flame Sensor Was Clean And Putting Out The Correct Micro Amps. The Furnace Cycled And Lit 8 Times For Me And Didn't Fail. I Changed The Control Board Thinking It Might Be Bad And Throwing A False Code. I Can't Seem To Catch The Furnace Doing Anything Wrong. Changed .10 Pressure Switch To See If That Takes Care Of Problem Put Old Board Back On.
Joe, J. North Judson, IN
01-31-2024
Checked Furnace Found Upper Limit Switch Tripped. Reset Limit Switch And Furnace Ran Ok. Performed Clean And Tune On Furnace And Also Fixed Leak That Was Between Draft Inducer And Collector Box
Cohen, F. North Judson, IN
01-18-2024
Changed Heat Strip
Steve, L. North Judson, IN
12-21-2023
Checked Furnace Found Board Not To Be Sending Power To Blower. Checked Board Found Burnt Spot, Changed Board Unit Ran As It Should.
Fred, E. North Judson, IN
12-21-2023
Replaced The Ignitor On The Furnace
William , W. North Judson, IN
12-21-2023
Changed Heat Strip, Checked Temperature Rise Unit Ran As It Should
Steve, L. North Judson, IN
12-14-2023
Goodman GKS90904CX
Replaced Circuit Board On Furnace
Laura, B. North Judson, IN
12-11-2023
Goodman GCH950905D
Cleaned Flame Sensor, Cleaned Trap Assembly, Checked Pressure On Pressure Switches, Checked Filter.
Joe, J. North Judson, IN
11-28-2023
Heil Heating & Cooling N9MSE0801716A
Checked Furnace, Found In A Pressure Switch Lockout. Cleaned Trap Assembly, Blew Out Pressure Switch Tubes. Checked Pressure On Tubes, Found It Way Over What Was Needed To Pull In Switches. Cycled Furnace, It Did Not Go Out On Pressure Switch But After A While It Cycled On Limit Switch
Clayton, H. North Judson, IN
11-28-2023
Heil Heating & Cooling N9MSE0801716A
Installed New Draft Inducer Furnace
Clayton, H. North Judson, IN
11-22-2023
Replaced Shut Off Valve On Furnace And On Water Heater. I Disconnected The Gas Line From The Basement And Plugged It.
Monty, G. North Judson, IN
11-15-2023
I Cleaned The Burners On The Hanging Heater.
Gary, R. North Judson, IN
11-15-2023
Started Unit Up Set Thermostat To 64, Wall Unit Was Firing Up And Running.
Diana, S. North Judson, IN
11-02-2023
Bryant
Replaced The Indoor Blower Capacitor On The Furnace
Christy, H. North Judson, IN
10-30-2023
Nordyne Heating & Air M1GB 070A BW
The Customers Draft Inducer On Their Nordyne M3RL060A BW Was Bad And The Technician Replaced It.
John, L. North Judson, IN
04-12-2023
Replacement Of 4
Apex, W. North Judson, IN
02-14-2023
American Standard HVAC ADC1B080A9421A
Clients American Standard ADC080C942BA Gas Furnace Had A Faulty Control Board And High Limit Switch. The Technician Replaced Both Parts And The System Is Operating Properly
Larry, . North Judson, IN
12-02-2022